Kleinwächter EFM-022 Electrostatic Field Meter Operation Manual
This document is the operation manual for the Kleinwächter EFM-022 Electrostatic Field Meter. It details the use of various kits (CPS, VMS) to measure surface static voltage, electrostatic field strength, ionizer balance/dissipation time, and human walking static voltage. The meter features a rotating vane probe with high sensitivity and a wide measurement range.
Read onlineKleinwächter EFM-022 specifications
| Static Voltage Range (2cm) | 0~20KV |
|---|---|
| CPS Mode Voltage Range | 100~1000V |
| Measurement Accuracy | +/-5% |
| Power Supply | 9V battery |
Source: Kleinwächter EFM-022 Electrostatic Field Meter Operation Manual
All Kleinwächter EFM-022 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the default test distance for surface static voltage?
The default test distance is 2cm.
From: Kleinwächter EFM-022 Electrostatic Field Meter Operation Manual
How do you turn on and off the instrument?
Press the function key once to power on, or press it twice quickly to power off.
From: Kleinwächter EFM-022 Electrostatic Field Meter Operation Manual
What is the measuring range at a distance of 2cm?
At a distance of 2cm, the device can measure charges up to 20kV with a resolution of 2V.
From: Kleinwachter EFM 022 Electrostatic Field Meter User Manual
What is the maximum charge voltage measurable at a distance of 1cm?
The device can measure charges up to 10kV when set to a measurement distance of 1cm.
From: Kleinwachter EFM 022 Electrostatic Field Meter User Manual
How is the EFM-022 powered and what are the low‑battery warnings?
The instrument runs on a 9 V battery (ordinary or rechargeable). When the voltage drops below 7.6 V the screen shows “Low Battery”, and below 7.1 V it displays “auto off” and shuts down after 2 seconds.
From: Kleinwächter EFM-022 Electrostatic Field Meter and Kit Operation Manual
How do you change measurement modes on the EFM-022?
Long‑press the function key until “Change Mode” appears, then press the key once to cycle to the next mode. The instrument will start measuring in the selected mode after the indicator disappears.
From: Kleinwächter EFM-022 Electrostatic Field Meter and Kit Operation Manual