Key facts
- Brand
- JRC
- Model
- JUE-87
- Category
- Industrial Robot
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2023-10-19
Start here

JRC JUE-87 INMARSAT-C Mobile Earth Station User Manual
This is the user manual for the JRC JUE-87 INMARSAT-C Mobile Earth Station, a maritime satellite communication device. It provides detailed safety instructions, including warnings about high voltage and procedures for handling electrocution emergencies. The manual includes step-by-step first aid guidance for CPR and artificial respiration, with specific protocols for lone rescuers and teams. Safety precautions emphasize avoiding contact with internal components and ensuring power is disconnected before any maintenance or first aid.
Read onlineJRC JUE-87 specifications
| Frequency Range (Transmission) | 1626.5 to 1646.5MHz |
|---|---|
| Frequency Range (Reception) | 1537.0 to 1544.2MHz |
| Power Supply Voltage | DC +24V (+19.2 V to +31.2 V) |
| Data Rate | 600 bps |
| Max Transmission Message | 8K bytes |
| Max Reception Message Storage | 80K bytes |
| Operative Temperature (EME) | -35°C to +55°C |
| Dimensions (EME) | 170 mm (φ) × 379 mm (H) |
Source: JRC JUE-87 Inmarsat-C Mobile Earth Station Ship Security Alert System Option Operation Manual
All JRC JUE-87 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How should I perform CPR if alone?
Perform 15 chest compressions, then give 2 rescue breaths. Repeat this cycle until help arrives.
From: JRC JUE-87 INMARSAT-C Mobile Earth Station User Manual
How often should the recovery position be changed to maintain blood circulation?
You must roll the person gently to the opposite direction every 30 minutes.
From: JRC JUE-87 INMARSAT-C Mobile Earth Station User Manual
What regulations does this system meet?
The system meets SOLAS Chap. XI-2 Regulation 2&6, ISPS code Part A, 9.4.18, and IMO MSC Resolution 136(76)/147(77).
From: JRC JUE-87 Inmarsat-C Mobile Earth Station Ship Security Alert System Option Operation Manual
Can the user check or repair the internal equipment?
No, users should not check or repair internal equipment as it may cause fire, electrical shock, or malfunction.
From: JRC JUE-87 Inmarsat-C Mobile Earth Station Ship Security Alert System Option Operation Manual
What is the specific voltage range for the primary power of the JUE-87?
The primary power must be DC+24V within a range of +19.2 V to +31.2 V when using the standard PSU NBD-904.
From: JRC JUE-87 Inmarsat-C Mobile Earth Station User Manual
Can the user adjust the internal circuit or exchange parts of the JUE-87?
No, users must not adjust the internal circuit or exchange parts because the internal circuit is adjusted strictly by the manufacturer.
From: JRC JUE-87 Inmarsat-C Mobile Earth Station User Manual