Installation Guide 26 pages · 577 KB · EN

This guide provides step-by-step instructions for installing the Itron 100G Datalogging Gas Endpoint on a wide variety of gas meters. The device is an RF device designed to transmit meter data and stores up to 40 days of hourly data. Mechanical installation procedures are identical for both the standard 100G Gas Endpoint and the 100G Datalogging version.

Read online

Itron 100G Datalogging specifications

Tamper DetectionTilt tamper and magnetic tamper
Operating Temperatures-40° to 158° F (-40° to +70° C)
Operating Humidity5 to 95 percent relative humidity
Program Frequency908 MHz
Transmit Frequency908 to 924 MHz
Data IntegrityVerified in every data message

Source: Itron 100G Datalogging Installation Guide

All Itron 100G Datalogging documents by type

Installation Guide 2

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

What is the expected battery life in Fixed Network Mode?

The expected battery life is 20 years.

From: Itron 100G Datalogging Installation Guide

What is the expected battery life in Mobile and Handheld Mode?

The expected battery life is 20 years.

From: Itron 100G Datalogging Installation Guide

What software is required to program the 100G Datalogging Gas Endpoint?

The endpoint must be programmed with the FC200SR handheld computer loaded with EndPoint-Link or Point-Link Pro software version 5.3 or later.

From: Itron 100G Datalogging Gas Endpoint Installation Guide

What software version is required to program the 100G Datalogging Gas Endpoint?

Programming requires the FC200SR handheld computer loaded with EndPoint-Link or Point-Link Pro software version 5.3 or later.