Key facts
Start here

Invertek Optidrive ODE-3 AC Variable Speed Drive User Manual
This user guide covers the Invertek Optidrive ODE-3 AC variable speed drive range in IP20 and IP66 (NEMA 4X) enclosures, rated 0.37 kW to 22 kW (0.5 HP to 30 HP) with 110–480V three phase input. It is written for qualified electrical personnel and covers quick start-up, general information and ratings, mechanical installation, power and control wiring, operation and parameters.
The guide also covers analog and digital input macro configurations, Modbus RTU communications, technical data and troubleshooting with fault code messages. It is for use with version 3.05 firmware and is document revision 2.00; the manual states a 2 year warranty against manufacturing defects.
Invertek ODE-3 specifications
| Power range | 0.37–1.1 kW (0.5–1.5 HP) |
|---|---|
| Voltage | 110–230 V |
| Output phase | Single phase |
| Enclosure rating | IP20 and IP66 (NEMA 4X) |
| Relative humidity | Less than 95% (non-condensing) |
| Use environment | Indoor use only |
Source: Invertek Optidrive ODE-3 Single Phase Output AC Variable Speed Drive User Guide
All Invertek ODE-3 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What power range does the Optidrive ODE-3 cover?
It covers 0.37 to 1.1 kW (0.5 to 1.5 HP).
From: Invertek Optidrive ODE-3 Single Phase Output AC Variable Speed Drive User Guide
What voltage is stated for the drive?
The guide states 110 to 230 V.
From: Invertek Optidrive ODE-3 Single Phase Output AC Variable Speed Drive User Guide
¿Qué modelos cubre la guía del usuario ODE-3?
Cubre los convertidores de frecuencia Optidrive ODE-3 de salida monofásica, de 0.37 a 1.1 kW (0.5 a 1.5 HP) y 110 a 230 V, en versiones IP20 e IP66 (NEMA 4X).
From: Invertek Optidrive ODE-3 Frequency Converter User Guide
¿Con qué versión de firmware se usa esta guía?
La guía está prevista para usarse con la versión 3.02 del firmware.
From: Invertek Optidrive ODE-3 Frequency Converter User Guide
How long should I wait before working on the drive after removing the main supply?
Wait ten minutes for the high voltage capacitors to discharge to safe voltage levels before working on the drive.
From: Invertek Optidrive ODE-3 AC Variable Speed Drive User Manual
Which firmware version does this user guide apply to?
The guide is for use with version 3.05 firmware (user guide revision 2.00).
From: Invertek Optidrive ODE-3 AC Variable Speed Drive User Manual