Invertek Drives Optidrive E2 Frequency Controller Installation and Operation Manual

Invertek Drives Optidrive E2 Frequency Controller Installation and Operation Manual

User Manual 25 pages · 2.5 MB · NL

This Dutch-language manual covers the Invertek Drives Optidrive E2 frequency controller for a power range of 0.37-11kW, with IP20, IP55 and IP66 protection grades. It is presented as an installation and operation guide and includes a declaration of conformity for CE marking under the low-voltage and EMC directives.

The manual covers introduction and safety information, mechanical installation, main and control wiring, operation, parameters, digital and analog input configuration, technical specifications, additional IP66 information, and troubleshooting. Its safety section states that the drive is intended for professional use in industrial machines and describes high voltage and current risks, including waiting 10 minutes after switch-off before working on the drive. This manual is written in Dutch.

Read online

Invertek Drives Optidrive E2 specifications

Power range0.37-11kW
Protection gradesIP20, IP55 and IP66
Single-phase input230 Volt
Three-phase input400 Volt
Relative humidity limitBelow 95%

Source: Invertek Drives Optidrive E2 Frequency Controller Installation and Operation Manual

All Invertek Drives Optidrive E2 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What power range is covered by the Invertek Drives Optidrive E2 manual?

The manual lists a power range of 0.37-11kW.

From: Invertek Drives Optidrive E2 Frequency Controller Installation and Operation Manual

What protection grades are listed for the Optidrive E2?

The listed protection grades are IP20, IP55 and IP66.

From: Invertek Drives Optidrive E2 Frequency Controller Installation and Operation Manual

How long should I wait after disconnecting the Optidrive before working on it?

High voltages remain present for up to 10 minutes after the supply is disconnected, so isolate the drive and verify with a multimeter that no voltage is present before starting work.

From: Invertek Drives Optidrive E2 Variable Speed Drive User Guide

What enclosure protection does the Optidrive E2 have?

It has an Ingress Protection rating of IP20 or IP55 depending on the model, and IP20 units must be installed in a suitable enclosure.

From: Invertek Drives Optidrive E2 Variable Speed Drive User Guide