Invertek Drives Optidrive ODE-3 1Ph Output User Guide
The document serves as a comprehensive user guide for the Optidrive ODE-3 Single Phase Output AC Variable Speed Drive (0.37 – 1.1kW). It covers essential topics including quick start-up procedures, mechanical installation guidelines for both IP20 and IP66 units, and detailed power wiring instructions.
The manual details drive operation via keypad management, parameter setting, and fault resetting. It also explains analog and digital input macro configurations, Modbus RTU communications setup, technical data specifications, and troubleshooting methods for various fault code messages.
Invertek Drives Optidrive ODE-3 specifications
| Power Rating | 0.37 – 1.1kW (0.5 – 1.5HP) |
|---|---|
| Input Voltage | 110 – 230V |
| Warranty Period | 2 years |
Source: Invertek Drives Optidrive ODE-3 1Ph Output User Guide
All Invertek Drives Optidrive ODE-3 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the minimum separation required between control and power cabling?
A minimum separation of 100 mm must be maintained wherever control cabling is close to power cabling.
What firmware version does this user guide support?
This User Guide is for use with version 3.02 Firmware.
What voltage range does the Optidrive ODE-3 support?
The drive is rated for 110–480 V.
From: Invertek Drives Optidrive ODE-3 AC Variable Speed Drive User Guide
What enclosure ratings are available?
The drive is available in IP20 and IP66 (NEMA 4X) versions.