Hohner CM26M Manuals

ManualLib has 2 documents for the Hohner CM26M (Other device): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Hohner
Model
CM26M
Category
Other device
Documents
2
Languages
EN · ZH
Last added
2023-11-02

Start here

Hohner CM26M Multiturn Encoder Instruction Manual

Hohner CM26M Multiturn Encoder Instruction Manual

User Manual 2 pages · 302 KB · EN

The Hohner CM26M is a multiturn encoder with an adjustable electrical angle. At delivery, it is adjusted to an electrical angle of 20 turns (7200°), with the signal increasing when the shaft is turned clockwise as viewed from the shaft end.

The manual describes three adjustment modes: angle adjust, reference adjust and reset adjust. It also covers pin identification, connections, programming steps and storage of the adjusted start and end positions in flash memory.

Read online

Hohner CM26M specifications

Default electrical angle20 turns (7200°)
Signal periodicity11 turns
PlateauHalf turn (180°) on each side
Power supply16–30 VDC
Output signal0–5 V or 0–10 V
Maximum adjusting cycles10,000

Source: Hohner CM26M Multiturn Encoder Instruction Manual

All Hohner CM26M documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the default electrical angle of the CM26M at delivery?

At delivery, the encoder has an electrical angle of 20 turns (7200°).

From: Hohner CM26M Multiturn Encoder Instruction Manual

What supply voltage does the CM26M require?

The power supply input is 16 to 30 VDC.

From: Hohner CM26M Multiturn Encoder Instruction Manual

How is the rotation direction programmed?

Direction is programmed using terminal 6: leave it open for clockwise rotation or connect it to ground for counter-clockwise rotation.

From: Hohner CM26M Multi-Turn Absolute Encoder Programming Manual

What happens if the power is interrupted?

If power is interrupted or rotation exceeds ±179 degrees, the analog output signal value will not match the actual value and requires recalibration.

From: Hohner CM26M Multi-Turn Absolute Encoder Programming Manual