This document provides the programming manual for CM26M encoder, including default configuration settings, programming modes, and programming steps.
The Hohner CM26M is a multi-turn absolute encoder that outputs a signal with a default configuration of 3600 degrees (10 turns) and includes a dead zone of 180 degrees. The device supports three distinct programming modes: Angle Mode for configuring output range and direction, Reference Mode for setting the current position as zero, and Reset Mode to restore factory defaults.
Programming is performed by connecting specific cables to the encoder's terminals (Ground, Analog Output, Vcc, Set Start, Set End, and Direction). The Angle Mode requires precise rotation to set the number of turns, while the Reference Mode is used to recalibrate the zero signal after power loss or large mechanical rotation. All settings are retained until a new programming process is initiated. This manual is written in Chinese.
| Default Output Configuration | 3600 degrees (10 turns) |
|---|---|
| Dead Zone | 180 degrees (half turn) |
| Output Signal Period | 11 turns |
| Analog Output Voltage | 0 to 5V or 0 to 10V |
| Supply Voltage (Vcc) | 16 to 30V |
| Direction Calibration Range | ±179 degrees |
Direction is programmed using terminal 6: leave it open for clockwise rotation or connect it to ground for counter-clockwise rotation.
If power is interrupted or rotation exceeds ±179 degrees, the analog output signal value will not match the actual value and requires recalibration.