User Manual 100 pages · 5 MB · EN

The Fox Thermal Instruments Model FT3 is a microprocessor-based thermal mass gas flow meter and temperature transmitter. It operates by measuring heat transfer from a heated sensor to determine mass velocity, providing accurate measurements independent of temperature and pressure changes. The device features two galvanically isolated 4-20mA analog outputs, one for flow rate and another programmable for flow or temperature.

Read online

All Fox Thermal Instruments FT3 documents by type

Questions answered in these manuals

What does the CAL-V test verify?

It verifies the functionality of the sensor and its associated signal processing circuitry.

From: Fox Thermal FT3 Thermal Mass Flow Meter and Temperature Transmitter Calibration Validation User's Guide

How long does the CAL-V test take?

The test takes about 4 minutes to complete.

From: Fox Thermal FT3 Thermal Mass Flow Meter and Temperature Transmitter Calibration Validation User's Guide

When must the Zero CAL-CHECK test be performed?

The Zero CAL-CHECK test must be performed at a 'no flow' condition.

From: Fox Thermal Instruments FT3 Calibration Validation User's Guide

How can zero flow be achieved without stopping the process?

Zero flow can be achieved in-situ using a Fox Packing Gland Assembly to retract and isolate the sensor from the process.

From: Fox Thermal Instruments FT3 Calibration Validation User's Guide

What is the Model FT3?

The Model FT3 is a Thermal Mass Gas Flow Meter and Temperature Transmitter that measures mass flow in units like kg/hr, lb/hr, SCFM, SLPM, NM3/hr, or NLPM.

From: Fox Thermal Instruments FT3 Thermal Mass Flow Meter & Temperature Transmitter User Manual

How much straight pipe is required for an insertion-style installation?

Fifteen diameters of straight pipe are recommended upstream and ten diameters downstream to ensure a consistent flow profile.