Key facts
- Brand
- EUCHNER
- Model
- GS...C1806 12 mm
- Category
- Automation control Equipment
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2026-11-17
Start here

EUCHNER GS...C1806 12 mm Precision Combination Travel Switch User Manual
The EUCHNER GS...C1806 12 mm precision combination travel switch is an interlocking device without a door lock (category 1) used with movable safety guards and machine control systems to prevent dangerous machine functions when the safety door is open.
This user manual provides instructions for correct use, safety precautions, installation requirements, electrical connection, and function testing. It applies to positioning and control applications in mechanical and systems engineering. This manual is written in Chinese.
EUCHNER GS...C1806 12 mm specifications
| Housing Material | Cast aluminum, anodized |
|---|---|
| Plunger Material | Stainless steel |
| Protection Rating | IP67 |
| Mechanical Operating Cycle | 30x10^6 |
| Switching Frequency | 300 min^-1 |
| Operating Temperature | -5 ...+80 °C |
| Max Approach Speed (Roller R) | 80 m/min |
| Max Approach Speed (Roller B) | 120 m/min |
| Max Approach Speed (Circular W/Spherical K) | 10 m/min |
| Min Approach Speed | 0.01 m/min |
| Actuation Force | ≥ 20 N |
| Switch Elements | 1 NO + 1 NC contact |
| Switch Principle | Snap-action contact |
| Magnetic Hysteresis | 0.8 mm |
| Contact Material | Silver alloy, electrically bright gold |
| Wiring Method | Screw terminals |
| Rated Insulation Voltage | Ui = 250 V |
| Rated Impulse Withstand Voltage | Uimp = 2.5 kV |
| Category AC-12 | 250 V 8 A |
| Category AC-15 | 230 V 6 A |
| Category DC-13 | 24 V 6 A |
Source: EUCHNER GS...C1806 12 mm Precision Combination Switch User Manual
All EUCHNER GS...C1806 12 mm documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What tightening torque is required for the switch cover?
The tightening torque for the switch cover is 1.5 Nm.
From: EUCHNER GS...C1806 12 mm Precision Combination Travel Switch User Manual
Which switching element must be used when the device is used as a safety switch?
Only the ES508E switching element with positive opening contacts may be used.
From: EUCHNER GS...C1806 12 mm Precision Combination Travel Switch User Manual
What documents are required for complete user information?
The user manual must be read together with the "Safety Information and Maintenance" document and any provided datasheets.
From: EUCHNER GS...C1806 12 mm Precision Combination Switch User Manual
Who is authorized to perform installation and electrical connections?
Installation and electrical connection work must be performed by authorized personnel.
From: EUCHNER GS...C1806 12 mm Precision Combination Switch User Manual