Elcometer 280 Pulsed DC Holiday Detector User Guide

Elcometer 280 Pulsed DC Holiday Detector User Guide

User Manual 112 pages · 8.8 MB · EN

The Elcometer 280 is a Pulsed DC Holiday Detector designed to detect coating flaws by generating a high voltage at the probe tip. The device is available in two models, Model S and Model T, which share similar core functions but differ in menu structures and specific accessories like the voltage calculator found in the Model T. The guide provides detailed instructions on working safely, fitting the rechargeable battery pack, connecting the signal return lead, and selecting the appropriate test voltage.

Read online

Elcometer 280 specifications

Pulsed DC High Voltage Range0.5kV - 35kV
High Voltage Output Accuracy±5% or ±50V below 1000 Volts
Pulse Repetition Rate~30Hz
Operating Temperature0°C to 50°C (32°F to 120°F)
Weight3.0kg (6.6lb)

Source: Elcometer 280 Pulsed DC Holiday Detector User Manual

All Elcometer 280 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum coating thickness the Elcometer 280 can detect?

The device can detect porosity in coatings up to 25mm (1") thick.

From: Elcometer 280 Pulsed DC Holiday Detector User Manual

How long does the battery last?

Battery life depends on voltage and load; for a 12" Rolling Spring, it lasts 30 hours at 10kV and 12 hours at 35kV.

From: Elcometer 280 Pulsed DC Holiday Detector User Manual

What is the voltage range for the Elcometer 280?

The Elcometer 280 has a selectable voltage range of 0.5 to 35kV.

From: Elcometer 270/280/266 Microvoid and Porosity Detector User Manual

What standards does this equipment comply with?

The equipment complies with standards including ASTM D5162-A, ISO 8289-A, NACE RP 0188, and others listed in the manual.

From: Elcometer 270/280/266 Microvoid and Porosity Detector User Manual

What is the maximum voltage the Elcometer 280 can generate?

The device generates a voltage at the probe tip of up to 35,000V.

From: Elcometer 280 Pulsed DC Holiday Detector User Guide

How long does it take to fully charge the battery?

It takes approximately 4 hours to fully charge the battery.

From: Elcometer 280 Pulsed DC Holiday Detector User Guide