dIXEL XR75CX Manuals

ManualLib has 2 documents for the dIXEL XR75CX: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
dIXEL
Model
XR75CX
Documents
2
Languages
ZH
Last added
2026-10-28

Start here

DIXEL XR75CX Micro Electronic Thermostat User Manual

DIXEL XR75CX Micro Electronic Thermostat User Manual

User Manual 7 pages · 633 KB · ZH

The DIXEL XR75CX is a micro electronic thermostat designed for medium and low-temperature forced air-cooling refrigeration systems. It features four output channels for controlling the compressor, evaporator fan, defrosting (electric or hot gas), and a multi-function relay. The device includes a built-in real-time clock (RTC) for scheduling up to six defrost cycles per day, distinguishing between weekdays and holidays, and supports different setpoints for day and night operation to save energy. This manual is written in Chinese.

Read online

dIXEL XR75CX specifications

Dimensions32 x 74 x 60 mm
InputsUp to four NTC or PT1000 probes
CommunicationRS485 compatible with ModBUS-RTU

Source: DIXEL XR75CX Micro Electronic Thermostat User Manual

All dIXEL XR75CX documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

Can the XR75CX be used as a safety protection device?

No, the manual states it cannot be used as a safety protection device.

From: DIXEL XR75CX Micro Electronic Thermostat User Manual

How many defrost cycles can be scheduled per day?

The controller can schedule up to six defrost cycles per day.

From: DIXEL XR75CX Micro Electronic Thermostat User Manual

What is the maximum allowed instantaneous current for the output relays?

The maximum allowed instantaneous current for each output relay is specified in the technical data section.

From: dIXEL XR75CX Mini Electronic Temperature Controller Installation and Operating Manual

How does the defrost function work?

Defrost can be set to electric heating (tdF=EL) or hot gas (tdF=in). With RTC, defrost can be scheduled by time or triggered by clock parameters.

From: dIXEL XR75CX Mini Electronic Temperature Controller Installation and Operating Manual