Crouzet CIM 36 x 37 Series Current Meter Datasheet
This document provides technical specifications for the Crouzet CIM 36 x 37 series current meter, specifically model 99776602. The device features a 6-digit display with a height of 4 mm and operates on voltages ranging from 110 VDC to 230 VAC. It supports a maximum count rate of 25 impulses per second for DC and 18 impulses per second for AC.
Read onlineCrouzet CIM 36 x 37 specifications
| Number of digits | 6 |
|---|---|
| Operating frequency | 50 / 60 Hz |
| Counting capacity (without manual reset) | 999,999 impulses |
| Max. count rate (VAC) | 18 impulses/s |
| Mechanical life | > 50 x 10^6 operations |
| Temperature limits use | - 10 →+60 °C |
| Housing protection | IP40 |
All Crouzet CIM 36 x 37 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the part number for the CIM 36 x 37 current meter without manual reset?
The part number is 99776602.
What is the maximum count rate for DC voltage?
The maximum count rate for DC voltage is 25 impulses per second.
Does the CIM 36 x 37 come with a manual reset?
It is available with or without a manual reset.
What is the maximum count rate for VDC?
The maximum count rate for VDC is 25 impulses/s.
What is the part number for this product?
The part number is 99776613.
From: Crouzet CIM36x37-Screw 36 x 37 Screw manual reset Product Leaflet
What is the counting capacity without manual reset?
The counting capacity is 999,999 impulses without manual reset.
From: Crouzet CIM36x37-Screw 36 x 37 Screw manual reset Product Leaflet