Key facts
- Brand
- Blue Sky Energy
- Model
- SC30-LVD
- Industry
- Electronics
- Documents
- 2
- Languages
- EN
- Last added
- 2023-10-18
Start here

Blue Sky Energy SC30-LVD Solar Charger Installation and Operation Manual
This manual provides step-by-step instructions for installing and operating the Blue Sky Energy SC30-LVD solar charge controller. It covers safety precautions, charge control modes, display functions, wiring, and troubleshooting. The SC30-LVD includes Low Voltage Disconnect (LVD) and lighting control features. The device is designed for 12V lead-acid batteries and uses pulse width modulation to optimize charging.
The manual includes detailed diagrams, tables for charge settings, and safety warnings for handling batteries and electrical installations. It also explains how to configure charge parameters, connect PV modules and batteries, and interpret the digital display and status LEDs.
Blue Sky Energy SC30-LVD specifications
| Voltage | 12VDC |
|---|---|
| Current | 30A |
| Charge Control Type | Pulse Width Modulated (PWM) |
| Battery Chemistry | Flooded or sealed type lead-acid |
| Maximum PV Voltage | 24V |
| Maximum PV Current | 27A |
| Battery Voltage Range | 20 to 2,000 amp-hours |
Source: Blue Sky Energy SC30-LVD Solar Charger Installation and Operation Manual
All Blue Sky Energy SC30-LVD documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the maximum voltage and current the SC30-LVD can handle from a PV array?
The SC30-LVD must not be connected to a PV array producing more than 24 volts open circuit voltage (VOC) or 27 amps short circuit current (ISC).
From: Blue Sky Energy SC30-LVD Solar Charger Installation and Operation Manual
What is the battery voltage range supported by the SC30-LVD?
The SC30-LVD is designed for 12V lead-acid batteries with a capacity range of 20 to 2,000 amp-hours.
From: Blue Sky Energy SC30-LVD Solar Charger Installation and Operation Manual
What battery chemistry is this controller designed for?
The unit is designed to charge 12 volt flooded or sealed type lead-acid chemistry batteries.
What is the maximum PV short circuit current allowed?
The PV array must not be capable of producing greater than 27 amps of short circuit current.