Zhongchuang Zhihe ZH-40243-14F2 24-Channel AC Current and Voltage (Mixed) Acquisition Module User Manual

User manual for the Zhongchuang Zhihe ZH-40243-14F2 24-channel AC current and voltage acquisition module with RS485 Modbus-RTU.


Zhongchuang Zhihe ZH-40243-14F2 24-Channel AC Current and Voltage (Mixed) Acquisition Module User Manual - cover page
Brand
中创智合
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
447 KB
Published
15 November, 2026
Updated
15 November, 2026
MD5 checksum
2C02CFFE3A4A8121A0CF7B9E6FA1C58B

About this manual

The Zhongchuang Zhihe ZH-40243-14F2 is a 24-channel data acquisition module for AC current or voltage, with mixed current and voltage input supported. It uses high-precision current/voltage transformers and a true RMS measurement chip, and communicates over RS485 using the Modbus-RTU protocol.

The manual covers product overview, model variants, performance specifications, appearance and installation dimensions, wiring instructions, and Modbus communication protocol details including register definitions and command examples. Applications mentioned include street-light monitoring, production automation testing, and LED lamp aging testing. This manual is written in Chinese.

What's inside

  • Product Overview
  • Product Models
  • Performance Specifications
  • Appearance and Installation Dimensions
  • Wiring Instructions
  • Modbus Communication Protocol
  • Message Format
  • Register Definitions
  • Command Examples

Specifications

Channels24
Measurement typeAC current or voltage; mixed input supported
Accuracy0.2%
AC current ranges0-10 mA / 100 mA / 0-1 A / 0-5 A AC
AC voltage ranges0-10 V / 100 V / 300 V / 450 V AC
Input impedanceVoltage channels: 2 kΩ/V; current channels: 0 Ω
Operating temperature-20°C to +60°C
Data update time100 ms default; settable to 80, 60, 40, 20, 400, 1000 ms
Isolation withstand voltage>2500 VDC
Auxiliary power+9 to +30 VDC or +9 to +55 VDC (model dependent)
Power consumption<2 W (typical 24 V supply <40 mA)
Communication interfaceRS485, Modbus-RTU, bus load up to 255 devices
Baud rates2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data formatOdd/even/no parity (default no parity), 8 data bits, 1 stop bit
Dimensions217 x 112 x 47 mm
Screw mounting dimensions198.2 x 98 mm
Mounting hole diameter4.5 mm
Data output scaling24 AC current/voltage values; output 10000 corresponds to rated range
Frequency range (channels 13-24)30-100 Hz
Zero-point shielding0-50 (maximum shielding value is 0.5% of range)
Response time settings100, 80, 60, 40, 20, 400, 1000 ms

Frequently asked questions

How many channels can the module measure?

It can measure 24 channels of AC current or voltage.

What communication protocol does the module use?

It uses an RS485 interface with the standard Modbus-RTU protocol.

What is the measurement accuracy?

The accuracy class is 0.2%.

How can the default address and baud rate be restored?

Short INIT and G1, then power on; this is only effective in software setting mode.