User manual for Zhengzhou Winsen F1032 flow sensor with technical specs, pin definitions, and usage guidelines.
This document provides instructions for using the F1032 flow sensor, including technical specifications, pin configurations, and application scenarios. It details operating parameters such as voltage, current, temperature range, and output voltage types. Safety precautions are included to prevent damage from incorrect usage or environmental exposure.
The sensor uses MEMS technology for precise gas flow measurement and includes temperature compensation. It is suitable for medical oxygen delivery, combustion control, and portable instruments. This manual is written in Chinese.
| Full Scale Output Voltage | 4.90 - 5.10 V |
|---|---|
| Zero Flow Output Voltage | 0.96 - 1.04 V |
| Output Impedance | 200 Ω |
| Operating Voltage | 7.0 - 14.0 V |
| Operating Current | 15 - 30 mA |
| Accuracy | ±1.5% to ±2.5% F.S |
| Repeatability | ±0.3% to ±0.5% F.S |
| Annual Drift | ±0.1% to ±0.5% F.S |
| Operating Pressure | up to 600 kPa |
| Response Time | 5 - 15 ms |
| Operating Temperature | -25 to 65°C |
| Storage Temperature | -40 to 90°C |
| Flow Range | 20, 35, 50, 100, 150, 200 SLM |
The output voltage range is 4.90 to 5.10 V for full scale and 0.96 to 1.04 V for zero flow.
Operating temperature is -25 to 65°C, and storage temperature is -40 to 90°C.
It is suitable for medical oxygen delivery, combustion control, and portable instruments.