User manual for the MEu-CO carbon monoxide gas sensor, covering installation, operation, maintenance, technical specs, and safety precautions.
This user manual provides instructions for installing, operating, and maintaining the MEu-CO carbon monoxide gas sensor. It includes technical specifications such as detection range (0–1000 ppm), response time (<15s), and operating conditions (–20°C to +40°C). Safety precautions are detailed, including avoiding welding, preventing physical damage, and not sealing the sensor with resin or in oxygen-free environments. The sensor is designed for industrial and environmental CO detection applications. This manual is written in Chinese.
| Detection Gas | Carbon Monoxide (CO) |
|---|---|
| Range | 0~1000ppm |
| Response Time (T90) | <15S |
| Operating Temperature | -20℃~﹢40℃ (continuous), -40℃~﹢55℃ (intermittent) |
| Operating Humidity | 15%RH~90%RH (no condensation) |
| Sensitivity | (0.085±0.015) µA/ppm |
| Zero Point Drift | <±10ppm (equivalent CO) from -40℃ to +50℃ |
| Expected Lifespan | 3 years (in air) |
The detection range is 0 to 1000 ppm.
The response time (T90) is less than 15 seconds.
Continuous operation: -20°C to +40°C; intermittent operation: -40°C to +55°C.
No, it cannot be sealed with resin or stored in oxygen-free environments as it will damage performance.