York TP9C*C Multi-Position Natural Gas Furnace Technical Guide

York TP9C*C multi-position natural gas furnaces technical guide with ratings, dimensions, accessories, and installation clearances.


York TP9C*C Multi-Position Natural Gas Furnace Technical Guide - cover page
Brand
YORK
Category
Heater
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
134 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1191EADF828FED77DFC1D656466B2341

About this manual

York TP9C*C multi-position natural gas furnaces are compact induced-combustion units with modulating operation from 100% to 35% input and AFUE up to 98%. They are factory shipped for upflow or horizontal installation and may be converted for downflow.

The guide lists cabinet dimensions, ratings, electrical data, filter performance, accessories, recommended filter sizes, and clearances to combustibles.

What's inside

  • Warranty Summary
  • Description
  • Features
  • Cabinet and Duct Dimensions
  • Ratings & Physical / Electrical Data
  • Filter Performance
  • Accessories
  • Recommended Filter Sizes
  • Unit Clearances to Combustibles

Specifications

AFUEUp to 98%
Input capacity60-120 MBH (natural gas)
Modulation range100% to 35% of input
Cabinet height33 in
Control transformer24 V, 40 VA
Vent connection2 in
Airflow leakageLess than 1% of nominal airflow
Filter air velocity (throwaway filters)Not to exceed 300 ft/min
Approved vent pipingSelkirk Polyflue, Duravent Polypro, Centrotherm Innoflue
Gas code categoryCategory IV

Frequently asked questions

What warranty is provided?

A 20-year limited warranty on heat exchangers in residential applications, a 10-year warranty in commercial applications, and a standard 5-year limited parts warranty; extended lifetime heat exchanger and 10-year limited parts warranty when registered online within 90 days.

Can these furnaces be converted to propane?

Yes, all models are convertible to use propane (LP) gas.

Are high-altitude kits required?

No high altitude kits are required.

What filter velocity limit applies to throwaway filters?

Air velocity through throwaway type filters may not exceed 300 feet per minute.