About this manual

This Installation, Operation, and Maintenance Manual (IOM-129, Rev. A) covers the Welker High Pressure Liquid Eliminator with Welker Probe, model LE2SS-KO-HP. The device is used in a pipeline to deliver a gas sample free of entrained liquid: pipeline product enters the probe, gas passes through the liquid eliminator to the outlet port while liquids are filtered out and drained back into the pipeline. The high pressure model is built to sustain pipeline pressures in excess of 3,000 psi without pressure reducing or regulating equipment.

The manual gives general information and a product description, system specifications, a labeled system diagram of the eliminator and probe parts, step-by-step installation instructions with recommended tools, and maintenance procedures including disassembly, cleaning and reassembly of the screen, PTFE element and O-ring. Welker recommends biannual maintenance under normal operating conditions and more frequent maintenance in severe service.

What's inside

  • General
  • Introduction
  • Description of Product
  • Specifications
  • System Diagram
  • Installation & Operations
  • Installation Instructions
  • Maintenance

Specifications

Products HeatedGases
Materials of Construction316 stainless steel, aluminum, Viton®, and PTFE; others available
Maximum Allowable Operating Pressure3,600 PSIG @ -20º F to 120º F (248.21 Bar @ -29º C to 48.9º C)
Sample Probe Pipeline Connection1/2", 3/4", or 1” MNPT; others available
Insertion LengthCustomer specified
Outlet Connection¼" or ½" FNPT
Auxiliary Connections¼" FNPT
Model NumberLE2SS-KO-HP

Frequently asked questions

What is the maximum allowable operating pressure of the LE2SS-KO-HP?

It is rated at 3,600 PSIG over a temperature range of -20º F to 120º F (248.21 Bar at -29º C to 48.9º C).

How often should the liquid eliminator be maintained?

Welker recommends biannual maintenance under normal operating conditions, with a more frequent schedule in severe service, dirty conditions or excessive cycling usage.

What must be done before maintaining or disassembling the unit?

Depressurize the pipeline and system and close all valves, then close the inlet valve and the bleed valve on the device.

What lubricant is used on the O-ring during reassembly?

The manual specifies Dow Corning 111 (DC 111) grease or an equivalent lubricant, applied lightly to the O-ring.