Installation, operation, and maintenance manual for the Welker CP-30SI constant pressure sample cylinder with solid indicator.
The manual begins with general information, a product description, a component diagram, and a specifications table. It explains that the CP-30SI maintains steady pressure on the cylinder, uses a pneumatic pre-charge, and has a solid indicator and indicating ring set for 80% capacity.
Installation and operations sections cover connecting the system, pre-charging, purging, and continuous sampling. Maintenance sections cover disassembly, maintenance, reassembly, cylinder cleaning, a safety warning for liquid sample cylinders, and troubleshooting.
| Products Sampled | Crude oil, condensate, refined hydrocarbons, water, and all other gas or liquid products compatible with materials of construction |
|---|---|
| Materials of Construction | Anodized Aluminum, Viton®, PTFE (others available) |
| Sample Volume | 5 gallons |
| Sample Inlet Connection | 1/4" NPT |
| Sample Outlet Connection | 1/4" NPT |
| Relief Valve Connection | 1/2"-20 UNF (1/4" NPT available) |
| Maximum Allowable Operating Pressure | 300 psi @-20°F to 120°F |
It is set to identify when the cylinder is at 80% capacity; sampling should be stopped at that mark.
Welker recommends annual maintenance under normal operating conditions, with more frequent maintenance for severe service.
The maximum allowable operating pressure is 300 psi at -20°F to 120°F.
Burst discs attached to each end cap rupture to relieve excess pressure inside the cylinder.