These Weidmüller VP***-WM explosion-proof stopping plugs are installed in unused entries of Ex equipment to maintain Flameproof Exd and Increased Safety Exe protection. The document covers the product description, certifications, selection requirements and installation instructions for hazardous-area use.
The text also lists installation torque values for metric and NPT threads, required ingress protection measures, routine checking and maintenance, marking interpretation, and the special conditions for safe use, including a service temperature of -50 °C to +120 °C. This manual is written in Chinese.
| Ingress protection | IP66/68 |
|---|---|
| Service temperature | -50 °C to +120 °C |
| Metric entry thread sizes | M16, M20, M25, M32, M40, M50, M63 |
| Installation torque, M16 & M20 | 32.5 N·m |
| Installation torque, M63 | 95.0 N·m |
| Metric thread standard | ISO 965-1 and ISO 965-3 |
-50 °C to +120 °C.
IP66/68.
32.5 N·m.
No. It should be fitted directly into unused entries of the equipment.