Viking Pump Series 480 Heavy-Duty Bracket Mounted Pumps Technical Service Manual

Viking Pump Canada technical service manual for Series 480 heavy-duty bracket mounted pumps, models J, K, KK, L, LQ and LL: maintenance, seals, troubleshooting.


Viking Pump Series 480 Heavy-Duty Bracket Mounted Pumps Technical Service Manual - cover page
Brand
Viking pump
Category
Industrial Supply
Document type
Service Manual
Language
English
Pages
12
File format
PDF
File size
1.7 MB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
19A76E5E64A71D06219E2A6E1C88F5C5

About this manual

This technical service manual (Section 3, Bulletin TSM480, Issue A) from Viking Pump Canada, a unit of IDEX Corporation, deals only with Series 480 heavy-duty bracket mounted pumps in models J, K, KK, L, LQ and LL. It covers maintenance, the sealed pump breakdown drawing, sealed pump disassembly and assembly, installation of the carbon graphite bushing, thrust bearing adjustment, pressure relief valve instructions and pressure adjustment, hydrostatic test, troubleshooting and pump inspection.

The manual states that its illustrations are for identification only and cannot be used for ordering parts; a parts list must be obtained from the factory or a Viking Canada representative, quoting the model and serial number from the nameplate. It also lists safety precautions to follow before opening any Viking pump liquid chamber, explains rotation and pressure relief valve requirements, and gives suggested repair tools and storage and lubrication instructions.

What's inside

  • Special Information
  • Maintenance
  • Sealed Pump Breakdown Drawing
  • Sealed Pump Disassembly
  • Sealed Pump Assembly
  • Thrust Bearing Adjustment
  • Pressure Relief Valve Instructions
  • Hydrostatic Test
  • Troubleshooting
  • Pump Inspection

Specifications

Series and modelsSeries 480 heavy-duty bracket mounted pumps, models J, K, KK, L, LQ and LL
RotationOperates equally well in clockwise or counterclockwise rotation
Suction port locationPort where the gear teeth come out of mesh
Factory lubricationAll pumps are greased at the factory
Bearing/idler pin lubricantNon-detergent SAE 30 weight oil
Relief valve bonnet positionMust point toward the suction side of the pump

Frequently asked questions

Which pump models does this manual cover?

It deals only with Series 480 heavy-duty bracket mounted pumps, models J, K, KK, L, LQ and LL.

Can the pump be run in either direction of rotation?

Yes. Rotary gear pumps operate equally well clockwise or counterclockwise, and the shaft rotation determines which port is suction and which is discharge.

What must be done before opening a Viking pump liquid chamber?

Any pressure in the chamber must be completely vented, the driving means must be locked out or made non-operational, and you must know what liquid the pump has been handling and the precautions for it.

Which way must the relief valve bonnet point?

The relief valve bonnet must always point towards the suction side of the pump.