Viking Pump Canada technical service manual for Series 480 heavy-duty bracket mounted pumps, models J, K, KK, L, LQ and LL: maintenance, seals, troubleshooting.
This technical service manual (Section 3, Bulletin TSM480, Issue A) from Viking Pump Canada, a unit of IDEX Corporation, deals only with Series 480 heavy-duty bracket mounted pumps in models J, K, KK, L, LQ and LL. It covers maintenance, the sealed pump breakdown drawing, sealed pump disassembly and assembly, installation of the carbon graphite bushing, thrust bearing adjustment, pressure relief valve instructions and pressure adjustment, hydrostatic test, troubleshooting and pump inspection.
The manual states that its illustrations are for identification only and cannot be used for ordering parts; a parts list must be obtained from the factory or a Viking Canada representative, quoting the model and serial number from the nameplate. It also lists safety precautions to follow before opening any Viking pump liquid chamber, explains rotation and pressure relief valve requirements, and gives suggested repair tools and storage and lubrication instructions.
| Series and models | Series 480 heavy-duty bracket mounted pumps, models J, K, KK, L, LQ and LL |
|---|---|
| Rotation | Operates equally well in clockwise or counterclockwise rotation |
| Suction port location | Port where the gear teeth come out of mesh |
| Factory lubrication | All pumps are greased at the factory |
| Bearing/idler pin lubricant | Non-detergent SAE 30 weight oil |
| Relief valve bonnet position | Must point toward the suction side of the pump |
It deals only with Series 480 heavy-duty bracket mounted pumps, models J, K, KK, L, LQ and LL.
Yes. Rotary gear pumps operate equally well clockwise or counterclockwise, and the shaft rotation determines which port is suction and which is discharge.
Any pressure in the chamber must be completely vented, the driving means must be locked out or made non-operational, and you must know what liquid the pump has been handling and the precautions for it.
The relief valve bonnet must always point towards the suction side of the pump.