This manual introduces the maintenance methods of Viking pumps, including storage, lubrication, oil quantity, periodic oil changes, plug locations, radial and overhung loads, troubleshooting, repair parts and warranty.
This document is a Technical Service Manual for Viking Pump in-line helical gear reducers, covering sizes 11 through 100. It provides detailed instructions on lubrication requirements, including oil quantities and viscosity selection based on ambient temperature and duty load. The manual distinguishes between 'life lubricated' units (sizes 11-41) and those requiring periodic oil changes (sizes 51-100).
| Product Type | In-line helical Gear Reducers |
|---|---|
| Covered Sizes | 11, 21, 31, 35, 41, 51, 61, 70, 80, 90, 100 |
| Lubrication Type (Sizes 11-41) | Life Lubricated with Synthetic Oil |
| Lubrication Type (Sizes 51-100) | User-filled Oil |
| Operating Temp Range (Life Lubricated) | -4°F (-20°C) to 122°F (50°C) |
| Warranty Period (Standard) | One year from date of startup |
No, sizes 11-41 are pre-filled with synthetic oil and lubricated for life.
Mineral Oil ISO VG 460 or Synthetic Oil ISO VG 320.
No, do not store outdoors or in areas exposed to weather or excessive humidity.
Check if gears are damaged, as this is a listed cause for this issue.