Service and operating manual for VERSAMATIC VM air lubricators, covering installation, lubrication, adjustment, maintenance, cleaning, and limits.
The VERSAMATIC VM Air Lubricators service and operating manual provides original instructions for installing, operating, and servicing the lubricator. It covers installation, application limits, lubricant selection, filling, adjustment, maintenance, cleaning, and operating limits for units with polyurethane or zinc bowls.
The document lists accessory part numbers for 1/4-inch, 1/2-inch, 3/4-inch, and 1-inch units and includes warnings about compressed air, electrical supply, chemical compatibility, and cleaning. It also gives maximum operating pressures and temperature ranges for polyurethane-bowl and zinc-bowl units.
| Maximum operating pressure, polyurethane bowl (1/4, 1/2, 3/4 units) | 1034 kPa (150 psig, 10 bar) |
|---|---|
| Operating temperature range, polyurethane bowl | 4.4°C to 48.9°C (40°F to 120°F) |
| Maximum operating pressure, zinc bowl (1-inch units) | 1723 kPa (250 psig, 17 bar) |
| Operating temperature range, zinc bowl | 4.4°C to 65.6°C (40°F to 150°F) |
| Recommended lubricant | High quality SAE #10 oil (S.U.V. 150-200 SEC @ 100°F) |
| Maximum alternative lubricant viscosity | SAE #40 (S.U.V. 800 SEC @ 100°F) |
Install it vertically with the bowl facing downward, as close as possible to the equipment being protected and after any filter/regulator. Air must flow in the direction of the arrow on top of the body.
For average conditions, the manual recommends high-quality SAE #10 oil; other lubricants may be used if not heavier than SAE #40.
Yes. The manual states that lubricators can be filled under pressure and without shutting down equipment.
Cessation of oil dripping through the sight dome, regardless of knob adjustment, indicates that cleaning is necessary.