This manual describes how to operate the Versa-Matic E5 series of plastic and metal pumps, including installation, startup and maintenance.
This document is the operating manual for Versa-Matic E5 plastic and metallic pumps, including models with polypropylene, Kynar, and acetal wetted parts, as well as aluminum, stainless steel, and Hastelloy C metallic versions. It provides essential information on model identification codes, safety warnings, and technical specifications.
| Flow Rate | 0-14 gpm (56 lpm) |
|---|---|
| Air Inlet Size | 3/8" NPT |
| Suction Lift (Rubber) | 20' (6.09 m) |
| Max. Particle Size | 0.0625" (1.66 mm) |
| Noise Level | 67.1 dB(A) |
| Max. Liquid/Air Supply Pressure (Plastic) | 100 psig (6.9 bar) |
| Max. Liquid/Air Supply Pressure (Metallic) | 125 psig (8.5 bar) |
| Displacement Per Stroke | 0.03 Gal. (0.11 L) |
The maximum suction lift for rubber wetted parts is 20 feet (6.09 meters).
Do not exceed 100 psig (6.9 bar) for plastic pumps.