User manual for VEICHI VC series unpowered I/O expansion modules, covering models, terminals, specifications, wiring, installation and checks.
This manual covers VEICHI VC series unpowered I/O expansion modules, including VC-0808ENR, VC-0808ENT, VC-1600ENN, VC-0016ENR and VC-0016ENT. It describes external structure, model naming, terminal definitions, electrical specifications, input and output characteristics, expansion bus connection and addressing, installation dimensions and routine and fault checks.
The modules connect to a VC series PLC main module through the expansion bus and are automatically identified and addressed by the PLC. This manual is written in Chinese.
| Input equivalent resistance | About 4.3 kΩ |
|---|---|
| Relay output external power | 250 Vac, below 30 Vdc |
| Relay output maximum current | 2 A per point; less than 8 A total for 8 points sharing COM |
| Transistor output external power | 5 to 24 Vdc |
| Transistor output maximum current | 3 A/1 point, 8 A/4 points, 1.6 A/8 points |
| 5 Vdc/GND current (VC-0808ENR) | 68 mA |
| Dielectric strength (relay output to expansion bus) | 2830 Vac for 1 minute |
| Maximum number of expansion modules | 15 |
Up to 15 total expansion modules, including special modules and I/O expansion modules.
Yes. The VC series PLC automatically identifies connected expansion modules and assigns addresses in sequence.
It supports sinking or sourcing inputs, selected by connecting S/S to +24 V or COM.
The internal equivalent input resistance is about 4.3 kΩ.