TRITECH TES-LC-30S Strain Gauge Center-Hole Load Cell User Manual

TRITECH TES-LC-30S strain gauge center-hole load cell user manual covering specifications, handling, cable connection, and installation.


TRITECH TES-LC-30S Strain Gauge Center-Hole Load Cell User Manual - cover page
Brand
Tritech
Category
sensor
Document type
User Manual
Language
Chinese
Pages
9
File format
PDF
File size
693 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
902FFD1DDFA34733B350D5C5BAD5D9A8

About this manual

TRITECH TES-LC-30S is a strain gauge center-hole load cell designed for civil engineering. It can measure tension in ground anchors, rock bolts, or warning retaining beams, and compressive loads in structural members such as tunnel supports or connections between crossbeams and pile columns.

The load cell uses eight strain gauges mounted at 45° and connected in a Wheatstone bridge circuit. It is electron-beam welded and sealed with an internal vacuum of 1/1000 Torr. Standard capacities range from 20 to 350 tf, and nonstandard internal diameters can be supplied on request. The manual covers specifications, handling, cable connection, required tools, installation, and troubleshooting. This manual is written in Chinese.

What's inside

  • Introduction
  • Specifications
  • Load Cell Handling
  • Support and Load Distribution Plates
  • Cable Connection
  • Tools and Accessories for Installation
  • Installation Procedure
  • Pre-installation Sensor Preparation
  • Load Cell Installation
  • Troubleshooting

Specifications

Standard capacity20/50/100/150/200/300/350 tf or as specified
Over-capacity range150%
Nonlinearity±1% fs (±0.5% fs available)
Output2 mV/V ±10%
Zero balance±5% fs
Excitation voltage10 V DC (maximum 20 V DC)
Input terminal resistance770 ohms ±5%
Output terminal resistance700 ohms ±1%
Operating temperature-10 to 55 °C
Element materialStainless steel 420
Internal vacuum1/1000 Torr

Frequently asked questions

What is the TES-LC-30S used to measure?

It is used in civil engineering to measure tension in ground anchors, rock bolts, or warning retaining beams, and compressive loads in structural members such as tunnel supports or connections between crossbeams and pile columns.

What is the standard capacity range?

Standard capacities range from 20 to 350 tf, and nonstandard internal diameters can be supplied on request.

How should the load cell be handled?

Avoid collisions during transport and installation, because impact can change the zero reading and may permanently damage the load cell.

What checks should be made before installation?

Measure resistance between the red and black terminals (770 ohms ±5%) and between the green and white terminals (700 ohms ±1%); lead-to-case resistance should be greater than 500 megohms.

Download PDF (693 KB)