TRITECH TES-LC-30S strain gauge center-hole load cell user manual covering specifications, handling, cable connection, and installation.
TRITECH TES-LC-30S is a strain gauge center-hole load cell designed for civil engineering. It can measure tension in ground anchors, rock bolts, or warning retaining beams, and compressive loads in structural members such as tunnel supports or connections between crossbeams and pile columns.
The load cell uses eight strain gauges mounted at 45° and connected in a Wheatstone bridge circuit. It is electron-beam welded and sealed with an internal vacuum of 1/1000 Torr. Standard capacities range from 20 to 350 tf, and nonstandard internal diameters can be supplied on request. The manual covers specifications, handling, cable connection, required tools, installation, and troubleshooting. This manual is written in Chinese.
| Standard capacity | 20/50/100/150/200/300/350 tf or as specified |
|---|---|
| Over-capacity range | 150% |
| Nonlinearity | ±1% fs (±0.5% fs available) |
| Output | 2 mV/V ±10% |
| Zero balance | ±5% fs |
| Excitation voltage | 10 V DC (maximum 20 V DC) |
| Input terminal resistance | 770 ohms ±5% |
| Output terminal resistance | 700 ohms ±1% |
| Operating temperature | -10 to 55 °C |
| Element material | Stainless steel 420 |
| Internal vacuum | 1/1000 Torr |
It is used in civil engineering to measure tension in ground anchors, rock bolts, or warning retaining beams, and compressive loads in structural members such as tunnel supports or connections between crossbeams and pile columns.
Standard capacities range from 20 to 350 tf, and nonstandard internal diameters can be supplied on request.
Avoid collisions during transport and installation, because impact can change the zero reading and may permanently damage the load cell.
Measure resistance between the red and black terminals (770 ohms ±5%) and between the green and white terminals (700 ohms ±1%); lead-to-case resistance should be greater than 500 megohms.