User manual for the Tekbox TBL5016-1 50µH Line Impedance Stabilisation Network (LISN) used for conducted noise measurements of DC or AC-powered equipment.
The Tekbox TBL5016-1 50µH LISN is a device designed for conducted noise measurements of DC or AC-powered electronic equipment, conforming to CISPR 16-1-2 and MIL-STD-461F standards. It operates in the frequency range of 9kHz to 100MHz and is used to establish a defined impedance for standardized tests.
The device features a 50Ω/50µH+5 Ω single line design and can be configured as a 50Ω/50µH LISN using a high current jumper. It is typically used in pairs for DC or single-phase measurements, while three or four units are required for 3-phase supply equipment depending on the configuration.
| Frequency range | 9 kHz – 100 MHz |
|---|---|
| DC Resistance | < 45 mΩ |
| Maximum current | 16A continuous |
| Operating voltage range | 0 – 250V DC; 0 - 250V AC (50/60 Hz), 0 – 90V AC (400 Hz) |
| Dimensions | 250 mm x 225 mm x 140 mm |
| Weight | 2.7 kg |
It can be configured by using a high current jumper to short the 5 Ohm resistor.
Since the LISN has no protective elements in the RF path, an external attenuator and/or limiter should be used if the DUT produces harmful transients.