TECH EU-MW-1/230 Wireless Controller User Manual

User manual for the TECH EU-MW-1/230 wireless controller module: installation, manual mode, pairing, factory reset, technical data and alarms.


TECH EU-MW-1/230 Wireless Controller User Manual - cover page
Brand
TECH
Category
Other
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
683 KB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
1366B8E0479F9B2A44DBE29142A3EF4C

About this manual

This user manual describes the EU-MW-1/230 (MW-1/230) wireless module made by TECH STEROWNIKI II Sp. z o.o. The module switches a potential-free contact when it receives a message from the main controller, so it can switch on a boiler, pump or valve actuators depending on the main controller. It communicates wirelessly and can work with up to 4 devices at the same time.

The document covers safety rules, device description and installation, manual mode, registration and advanced registration of devices, restoring factory settings, technical data, alarm behavior when communication is lost, and the EU Declaration of Conformity. It states that the device should be installed by a qualified electrician and that the power supply must be switched off before any work on the controller.

What's inside

  • Safety
  • Device Description
  • Installation
  • How to Use the Device
  • Manual Mode
  • Registration
  • Advanced Registration
  • Restore Factory Settings
  • Technical Data
  • Alarms

Specifications

Supply voltage100-240V / 50-60Hz
Operating temperature5°C - 50°C
Resistive load< 10 A
Maximum power consumption< 1 W
Operating frequency868 MHz
Maximum transmitting power< 25 mW

Frequently asked questions

How many devices can the MW-1/230 module work with at the same time?

It can cooperate with 4 devices at the same time, and at least one device must send a signal for the contact to be activated.

How long do I have to activate pairing on the main controller?

After pairing is started on the MW-1/230, the pairing option in the main controller must be activated within 2 minutes, otherwise the attempt fails.

What happens if the module loses communication with the main controller?

Communication is carried out every 4 minutes; without communication the receiver automatically disables the heating device contact after 15 minutes.

How do I restore the factory settings?

Press and hold the Manual mode button for 10 seconds until the two outermost control lights start flashing, then press the Pairing button.