Service manual for TCL wall-mounted split-type air conditioners, covering installation, troubleshooting, and maintenance for models including TAC-07HRA/E1…
This service manual provides technical guidance for servicing TCL wall-mounted split-type air conditioners. It includes product dimensions, refrigeration cycle diagrams, wiring diagrams, part lists, and operational details for various models. Sections cover installation, troubleshooting, disassembly, and operational modes including cooling, heating, and dry modes.
The manual also details remote controller settings, compressor control logic, fan speed regulation, and defrosting procedures. It is intended for technicians with electrical, electronic, and mechanical experience and includes safety precautions and part ordering instructions.
| Models Covered | TAC-07HRA/E1, TAC-07HA/E1, TAC-09HRA/E1, TAC-09HA/E1, TAC-12HRA/E1, TAC-12HA/E1, TAC-18HRA/E1, TAC-18HA/E1, TAC-24HRA/E1, TAC-28HRA/E1, TAC-36HRA/WE |
|---|---|
| Indoor Unit Dimensions (TAC-07HRA/E1) | 698 x 255 x 190 mm |
| Compressor Control Logic (Cooling Mode) | Compressor runs when RT - ST ≥ 1°C, stops when RT - ST < -1°C, holds state when -1°C ≤ RT - ST < 1°C |
| Compressor Control Logic (Heating Mode) | Compressor runs when ST - CRT ≥ 1°C, stops when ST - CRT < -1°C, holds state when -1°C ≤ ST - CRT < 1°C |
This manual covers models including TAC-07HRA/E1, TAC-07HA/E1, TAC-09HRA/E1, TAC-09HA/E1, TAC-12HRA/E1, TAC-12HA/E1, TAC-18HRA/E1, TAC-18HA/E1, TAC-24HRA/E1, TAC-28HRA/E1, and TAC-36HRA/WE.
The compressor runs when the room temperature minus the set temperature is greater than or equal to 1°C, stops when less than -1°C, and holds its current state when between -1°C and 1°C.