Service manual for the Tandberg 6000X tape recorder covering mechanical adjustments, tape path, head alignment, amplifier adjustment, modifications…
This service manual is for the Tandberg 6000X tape recorder. It covers mechanical adjustments including clutches, brakes, pressure pad, end stop mechanism, and tape path alignment.
It also describes bias and erase circuits, head alignment, track control, amplifier adjustment, tape speed control, modifications, lubrication, illustrations, spare parts lists, and wiring diagrams.
| Take-up turntable clearance | 0.5-0.9 mm |
|---|---|
| Brake pad clearance | approx. 1 mm |
| Pressure pad pressure | 80 g (2.8 oz) |
| Erase voltage | 80-120 V |
| Oscillator check receiver tuning | 256.5 kHz |
The voltage should be 80-120 V.
The clearance should be approximately 1 mm.
The pressure should be 80 g (2.8 oz).
It should be tuned to 256.5 kHz.