Talema AC1030 Current Transformer Datasheet

Technical datasheet for the Talema AC1030 30 Amp Current Transformer, detailing electrical specifications, excitation curves, and dimensions.


Talema AC1030 Current Transformer Datasheet - cover page
Brand
talema
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
1
File format
PDF
File size
55 KB
Published
04 November, 2026
Updated
04 November, 2026
MD5 checksum
18C3BB7085526E946B59A8784231154E

About this manual

This document is a datasheet for the Talema AC1030, a 30 Amp Current Transformer designed for low-cost applications. It covers electrical parameters, output voltage versus input current, and typical excitation curves for the AC1025~AC1030 series.

What's inside

  • Applications
  • Electrical Specifications
  • Output Voltage vs Input Current
  • Typical Excitation Curve
  • Notes
  • Dimensions

Specifications

Rated Primary Current30A
Operating Temperature-55°C to +85°C
Frequency Range50/60Hz
Primary Turns1 Turn
Primary Resistance100 ohms
Secondary Voltage (at 30A)3.0V

Frequently asked questions

What are the applications for the AC1030?

The AC1030 is suitable for sensing overload current, ground fault detection, metering, and analog to digital circuits.

Is the terminating resistor supplied with the AC1030?

No, unless specifically requested, the terminating resistor and the one-turn primary are not supplied.

What is the typical excitation curve range?

The typical excitation curve covers input currents from 0.1A to 100A and output voltages from 0.01V to 100V.