Technical datasheet for the TAIYO AHU2-063 series air oil unit, detailing format symbols, specifications, control methods, and application examples.
This document provides technical data for the TAIYO AHU2-063 Series Air Oil Unit. It explains how to construct model numbers using specific format symbols that define conversion capacity, valve types (flow or throttle), composite valves, control methods, solenoid voltage, and switch configurations.
The datasheet lists detailed specifications including working pressure ranges for different valve configurations, fluid requirements, and temperature limits. It also describes the unit's applications in hydraulic systems, such as intermediate stops, inching feeds, and speed switching.
| Working pressure range (Flow control with valve) | 0.2 ~ 1MPa |
|---|---|
| Pilot pressure (Flow control) | 0.3X main pressure + 0.25MPa |
| Withstanding pressure | 1.5MPa |
| Fluid type | General mineral hydraulic oil |
| Operating temperature range | -5 ~ + 50 ℃ |
The main pressure range goes up to 1 MPa.
It requires general mineral hydraulic oil.