The Surpon SPA-16DAH ampere‑hour meter manual provides specifications, installation, wiring, and operation instructions for industrial DC energy measurement.
This manual describes the SPA-16DAH ampere‑hour meter developed by Surpon. It outlines the device’s functions, such as 8‑digit cumulative ampere‑hour display, manual or automatic zeroing, configurable dosing time, power‑loss data retention, and optional RS485/RS232 communication.
The document includes technical specifications, mechanical dimensions, wiring instructions, key operation, parameter configuration, and communication settings, enabling proper installation and reliable use in chemical, electroplating, battery charging, and other industrial processes. This manual is written in Chinese.
| Input current signal range | 0~75 mV dc |
|---|---|
| Input signal accuracy | ≤0.2 % |
| Ampere‑hour display range | 0.00~99 999 999 AH |
| Current display range | 0~9999 |
| Communication interfaces | RS485 or RS232, Modbus RTU, address 0‑99, baud 2400‑19200 bps |
| Operating temperature | 0 ℃~50 ℃ |
| Isolation voltage | 2 kV/min AC |
| Dimensions (L×W×H) | 160 mm × 80 mm × 125 mm |
| Weight | ≈ 400 g |
Press and hold the increase key for more than 6 seconds in measurement mode to clear the cumulative ampere‑hour value.
Use parameter AL1H (address 00H) to set the ampere‑hour alarm value within the range 0‑9999.