User manual for the SUMTOR DM556-IO digital two-phase stepper driver, covering specifications, wiring, DIP switch settings, and auto-tuning.
The SUMTOR DM556-IO is a digital two-phase stepper motor driver using 32-bit DSP processing with variable-current and variable-frequency control. It supports 4, 6, and 8-wire two-phase step-in motors, automatic parameter tuning at power-up, and overvoltage, undervoltage, and overcurrent protection for small and medium automation equipment and instruments.
The manual covers electrical, environmental, and mechanical specifications, control signal interface circuits and timing, driver interfaces and wiring, status indicator fault codes, and DIP switch configuration for current, speed, static half-current, and parameter self-tuning. This manual is written in Chinese.
| Output current | 0.1 to 4.2 A |
|---|---|
| Input supply voltage | 24 to 50 VDC, typical 36 VDC |
| Control signal input current | 6 to 16 mA |
| Control signal interface level | 4.5 to 28 VDC |
| Insulation resistance | 100 MΩ |
| Operating humidity | 40 to 90%RH |
| Storage temperature | -20°C to 80°C |
| Weight | Approximately 280 g |
| Cooling method | Natural cooling or forced air cooling |
| Motor types supported | 4, 6, and 8-wire two-phase stepper motors |
| Current setting range | 0.1 to 5.6 A |
| Default speed setting range | 40 to 850 rpm |
| Pulse signal width | Greater than 1.5 μs |
| Direction signal lead time | At least 2 μs before pulse signal |
| Enable signal lead time | At least 5 μs before DIR |
| Overcurrent fault threshold | I peak ≥ 25 A |
| Overvoltage fault threshold | VDC ≥ 90 V |
| Undervoltage fault threshold | VDC ≤ 18 V |
The input supply voltage range is 24 to 50 VDC, with 36 VDC recommended for operation.
Output current is set with the SW1, SW2, and SW3 DIP switches, with selectable peak output values from 2.1 A to 5.6 A and a default of 1.0 A.
Move SW4 back and forth once within one second. During tuning, no pulse or direction signals should be applied or changed.
The red LED is the fault indicator and flashes on a 3-second cycle when a fault occurs. The number of flashes within 3 seconds identifies the fault type.