Stanford Research Systems SR620 Universal Time Interval Counter User Manual

Stanford Research Systems SR620 Universal Time Interval Counter user manual covering operation, setup, programming, specifications, testing, and calibration…


Stanford Research Systems SR620 Universal Time Interval Counter User Manual - cover page
Brand
Stanford Research Systems
Category
Counter
Document type
User Manual
Language
English
Pages
118
File format
PDF
File size
387 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
5A0EF89F8D591F2E1AF19C0DD918E16B

About this manual

The Stanford Research Systems SR620 is a Universal Time Interval Counter that measures time interval, pulse width, rise and fall times, frequency, period, phase, and event counting, with measurement statistics and graphics available in all operating modes. This Revision 2.2 manual (11/99) covers operation, setup, programming, specifications, testing, and calibration.

It applies to firmware versions 1.30 and greater and SR620 serial number 127 and higher. The instrument includes RS-232C and GPIB IEEE-488 remote interfaces, and the manual provides quick start instructions, front panel operation details, command references, performance tests, calibration procedures, and a circuit description with parts list.

What's inside

  • Specifications
  • Operation Quick Start Instructions
  • Front Panel Operation
  • Setting the Inputs
  • Programming the SR620
  • Test and Calibration
  • SR620 Circuitry
  • Component Parts List

Specifications

FunctionsTime Interval, Pulse Width, Rise and Fall Times, Frequency, Period, Phase, and Event Counting
Time Interval Range-1000 to +1000 s in +/- TIME mode; -1 ns to +1000 s in all other modes
Least Significant Digit4 ps single sample, 1 ps with averaging
Frequency Range0.001 Hz to 300 MHz via comparator inputs; 40 MHz to 1.3 GHz via internal UHF prescalers
Timebase Frequency10.000 MHz
Input Impedance(1 M Ohm + 30 pf) or 50 Ohms
Input Bandwidth175 MHz
DVM Accuracy0.3% of full scale
Power100, 120, 220 or 240 VAC +5% -10%, 50/60 Hz, 70 Watts
Weight11 lbs

Frequently asked questions

Which firmware versions does this manual cover?

It applies to firmware versions 1.30 and greater.

What remote control interfaces are available?

RS-232C and GPIB IEEE-488 interfaces are provided.

How much does the SR620 weigh?

It weighs 11 lbs.

What measurements can the SR620 make?

It measures time interval, pulse width, rise and fall times, frequency, period, phase, and event counts.