The Solinst STS Telemetry System User Guide explains setup, configuration, and data access for remote water monitoring.
Solinst STS Telemetry Systems provide an economical and efficient method to access remote water data instantly. They provide two-way communication between field located dataloggers and a Home Station computer, and up to four Solinst dataloggers can be connected to one STS.
The manual focuses on configuration, programming, and installation of STS Telemetry Systems using cellular communications. It includes instructions for installing and using Solinst Telemetry Software to set up data collection schedules, bridge RRL networks, manage data, perform diagnostic checks, and firmware updates.
| Compatibility | Up to four Solinst dataloggers |
|---|---|
| IP Rating | IP66 |
| Operating Temperature | -40ºC to 50ºC |
| Clock Accuracy | ±2 seconds/day @ 25ºC |
| Power Consumption | Average 23 mA @ 12 V (4 Loggers with 1 hour sampling rate and 1 day data report rate). |
Up to four Solinst dataloggers can be connected to one STS.
The operating temperature is -40ºC to 50ºC.
STS Systems are powered by a user-supplied 12V sealed lead-acid battery.