This manual covers installation, connection, debugging, electrical specifications, and troubleshooting for the Softlink IBX-234-401-E1 EtherCAT axis module.
The Softlink IBX-234-401-E1 EtherCAT Axis Module supports six-axis synchronous drive and digital I/O functions (8 outputs, up to 30 inputs). It is widely applicable in robotics, CNC machines, woodworking machinery, printing equipment, assembly lines, electronic processing equipment, laser processing equipment, and PCB drilling/milling devices. The module features reserved MPG handwheel interfaces and gLink-I bus expansion interfaces for flexible extension. This manual is written in Chinese.
| Power Supply Input | DC 24V (+10%) |
|---|---|
| Max Encoder Frequency | 2MHz |
| Max Pulse Output Frequency | 2MHz |
| Digital I/O Outputs | 8 channels |
The module requires a DC 24V power supply with a tolerance of +10%.
The module supports six-axis synchronous drive.