Installation and use manual for the Shurflo Model 100 single point pump, covering mounting, electrical connections, plumbing, and safety warnings.
This manual covers installation and use of the Shurflo Model 100 single point pump. It describes mounting position, electrical circuit requirements, plumbing, and required filtration.
It also states safety warnings, including no use in explosive environments, no dry running beyond one minute, and caution about liquid compatibility. Flow, pressure, wiring, and marine-use listing details are included. This manual is written in Portuguese.
| Maximum dry running time | Less than 1 minute |
|---|---|
| Open flow rate | Approximately 1 gallon per minute (4 L/min) |
| Maximum pressure | 10 psi (0.68 bar) at zero flow |
| Recommended wire size | 16 gauge or larger (1.2 mm²) |
| Inlet filter | 50 mesh filter required |
| Maximum mounting height above lowest water level | 4 inches (10 cm) |
| Recommended switch | 3.0 A switch |
| Marine listing (Nautilus Model 100) | ISO 8846 protection; U/L listed for marine use (ignition protection) for non-flammable liquids |
Yes. It can be installed in any position, but always at or below the bottom of the water tank and as close as possible to it.
Dry running can damage the shaft seal, and the maximum dry running time is less than one minute.
Yes. A 50 mesh filter must be installed in the inlet pipe between the tank and the pump inlet.
Do not assume compatibility; contact SHURFLO for compatibility or application information.