This manual introduces the installation and operation of the SHURFLO 4048 RV bypass pump, including installation preparation, installation and maintenance.
This manual provides guidelines for installing the Shurflo 4048 RV bypass pump to ensure quiet operation and good flow. Key installation requirements include mounting the pump on a solid surface within 6 feet of the tank, using flexible high-pressure hose, and ensuring proper wiring with a minimum of 14 AWG wire on a 10 Amp circuit. The pump is designed for intermittent duty only and should not be used for continuous reverse-osmosis filtration.
| Shut-off Pressure | 55 psi |
|---|---|
| Bypass Start Pressure | 30 psi |
| Full Bypass Pressure | 65 psi |
| Minimum Wire Size | 14 AWG [2.5mm²] |
| Recommended Wire Size | 12 GA [4mm²] |
| Minimum Power Requirement | 10 Amp circuit |
No, the pump is designed for intermittent duty only and should not be used for running a Reverse-Osmosis Filtration System.
The pump should be mounted within 6 feet of the tank for best performance and pump life.
Flexible high-pressure hose is recommended for the inlet and outlet to prevent noise and vibration.
Sanitizing is recommended prior to storing, after a period of storage, or any time the system is opened or contaminated.