This user manual for the Shidaigroup TV260 vibration measurement device covers structure, usage methods, performance specifications, precautions, and…
The document provides instructions for operating the TV260 handheld vibration meter. Users must press a button to start measurements within a range of 0.1 to 199.9 mm/s (rms). The device features a hold function and low battery indicators, requiring two LR44 or SR44 batteries with an estimated continuous working time of about 10 hours. This manual is written in Chinese.
| Measurement Range | 0.1mm/s to 199.9mm/s |
|---|---|
| Frequency Range | 10Hz to 1kHz |
| Frequency Response Error | ±10% (20Hz-1kHz), ±20% (10Hz-20Hz) |
| Power Source | 2 button cell batteries (LR44 or SR44) |
| Dimensions | 150mm x 22mm x 18mm |
The device measures a range from 0.1 to 199.9 mm/s (rms).
The device requires two button cell batteries, specifically LR44 or SR44.
The continuous working time is approximately 10 hours, and intermittent use lasts about 400 times.