This manual provides operating instructions, calibration methods, and technical specifications for the Shidai TT220 digital coating thickness gauge.
The document is a user manual for the Shidai TT220 digital coating thickness gauge. It covers the instrument's basic principles, which utilize magnetic induction to measure non-magnetic coatings on ferrous substrates and eddy current methods for non-ferrous metals. The device features single or continuous measurement modes, direct or batch data storage, and statistical analysis functions. This manual is written in Chinese.
| Measuring Range | 0~1250 µm |
|---|
The accuracy is ±(3%H+1) µm for single-point calibration and ±[(1%~3%)H+1] µm for two-point calibration.
Press and hold the 'MODE' key, then press the 'ON/C' key to toggle between SINGLE and CONTINUE modes.
The device calculates Mean (MEAN), Maximum (MAX), Minimum (MIN), Number of Tests (NO.), and Standard Deviation (S.DEV).