SENSIT Technologies GAS•TRAC LZ-30 Gas Leak Sensor User Manual

User manual for SENSIT Technologies' handheld methane gas detector with laser-based TDLAS technology, covering safety, operation, calibration, and maintenance.


SENSIT Technologies GAS•TRAC LZ-30 Gas Leak Sensor User Manual - cover page
Brand
SENSIT Technologies
Document type
User Manual
Language
Chinese
Pages
32
File format
PDF
File size
1.3 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
50B087E575C42BAF9B49B9B1DD8BA40C

About this manual

This is the user manual for the SENSIT Technologies GAS•TRAC LZ-30, a handheld laser-based methane gas detector. It uses Tunable Diode Laser Absorption Spectroscopy to measure methane concentration remotely up to 30 meters. The device features an OLED display, adjustable alarms, Bluetooth connectivity, and a rechargeable battery. Safety warnings cover laser hazards and explosive environments. Maintenance tips include keeping optics clean and using only approved chargers.

The manual includes sections on parts, specifications, operation, calibration, troubleshooting, and warranty. It also addresses WEEE compliance and provides contact details for technical support and repairs. This manual is written in Chinese.

What's inside

  • For Your Safety
  • Laser Warning Label Location
  • Contents
  • Parts And Accessories
  • General Description
  • Specifications
  • Product Features
  • Operation And Use
  • Calibration Check (Bump Test)
  • User Menu

Specifications

Detection TechnologyTunable Diode Laser Absorption Spectroscopy (TDLAS)
Methane Detection Range0-50,000ppm•m in 1ppm•m increments
Sensitivity5ppm•m ≤15m (50ft)/10ppm•m ≤30m (100ft) @ ≥ 300 ppm•m
Detection Distance0.5m to 30m (1.5’ to 100’)
Beam DimensionConical, 20cm diameter at 30m (8” at 100’)
Laser ClassificationsIR laser (methane detection) Class IIIR, Target laser (green) Class IIIR, Distance laser (red) Class IIIR
DisplayOLED
Operational Temp-20C to 50C (-4F to 122F)
Storage Temp-40C to 60C (-40F to 140F)
EnclosureIP54
Weight300g (0.7lbs)
Battery Life6 Hours Continuous

Frequently asked questions

What is the detection range of the GAS•TRAC LZ-30?

The methane detection range is 0-50,000ppm•m in 1ppm•m increments.

What laser classes does the device use?

The IR laser (methane detection) is Class IIIR, the target laser (green) is Class IIIR, and the distance laser (red) is Class IIIR.

How long does the battery last?

The battery provides 6 hours of continuous operation.

What is the operational temperature range?

The device operates between -20°C to 50°C (-4°F to 122°F).

Download PDF (1.3 MB)