The document from Shenzhen Senba Optical & Electronic describes the D203B series dual-element pyroelectric infrared radial sensor. It lists standard specifications and dimensions, including a TO-5 package, a 5–14 µm receiving wavelength, a 3–15 V supply voltage and an operating temperature range of -30 to 70 °C.

It also presents test methods, a typical application circuit with an LM324 IC and 12 V DC supply, notes on Rs value adjustment and window material transmission, Fresnel lens positioning, handling precautions and packaging quantities. This manual is written in Chinese.

What's inside

  • Standard Specifications and Dimensions
  • Test Method
  • Typical Application Circuit
  • Window Material Transmission Wavelength
  • Fresnel Lens for Detection Orientation
  • Usage Instructions

Specifications

ModelD203B series
Infrared receiving electrode2 × 1 mm, 2 sensing elements
Window size5 × 3.8 mm
Receiving wavelength5–14 µm
Output signal peak>3500 mV
Sensitivity3300 V/W
Detectivity (D*)1.4 × 10^8 cmHz^1/2/W
Noise peak<70 mV
Output balance<10%
Source voltage0.3–1.2 V
Supply voltage3–15 V
Operating temperature range-30 to 70 °C
Storage temperature range-40 to 80 °C

Frequently asked questions

What is the D203B sensor's supply voltage range?

The specified supply voltage range is 3 to 15 V.

What is the operating temperature range of the D203B sensor?

The operating temperature range is -30 to 70 °C.

What IC and supply are used in the typical application circuit?

The typical application circuit uses an LM324 IC with a 12 V DC supply.

What is the standard value of Rs?

The standard value of Rs is 47 kΩ; users can also adjust it for the required output voltage.