About this manual

This document provides step-by-step installation and operating instructions for Ringspann FRXF/FRXG freewheel backstops. It includes safety warnings, pre-installation checks, mounting procedures, operation guidelines, and maintenance protocols. The backstops are designed to protect conveyors and elevators from reverse runaway. Proper installation and lubrication are critical to ensure safe and long-term operation.

The document specifies shaft requirements, key installation, torque arm mounting, and operational speed limits for different models. Maintenance involves periodic grease seal purging using Mobilgrease XHP 221 or equivalent, with detailed procedures for grease flushing and reinstallation of set screws.

What's inside

  • Safety Notice
  • Pre-installation Check
  • General Instructions
  • Installation
  • Operation
  • Maintenance
  • Warranty
  • Backstop Rebuilding Service

Specifications

Lift Off Speed FRXF/FRXG 550700 rpm
Lift Off Speed FRXF/FRXG 700350 rpm
Shaft Finish Requirement125 micro inch or finer

Frequently asked questions

Can the backstop be mounted in any orientation?

Yes, the backstop rotational axis can be from horizontal to vertical, and the torque arm can be mounted at any desired angle.

What is the maximum operational speed for the FRXF/FRXG 775 model?

Maximum operational speed is 2100 rpm.

What lubrication is recommended for grease seal maintenance?

Mobilgrease XHP 221 or equivalent.

What should be done if the backstop is accidentally rotated in the wrong direction at start-up?

The backstop may have been damaged and should be returned to RINGSPANN CORPORATION for inspection.