Installation and operating instructions for Ringspann FRXF/FRXG freewheel backstops, including safety, mounting, operation, and maintenance.
This document provides step-by-step installation and operating instructions for Ringspann FRXF/FRXG freewheel backstops. It includes safety warnings, pre-installation checks, mounting procedures, operation guidelines, and maintenance protocols. The backstops are designed to protect conveyors and elevators from reverse runaway. Proper installation and lubrication are critical to ensure safe and long-term operation.
The document specifies shaft requirements, key installation, torque arm mounting, and operational speed limits for different models. Maintenance involves periodic grease seal purging using Mobilgrease XHP 221 or equivalent, with detailed procedures for grease flushing and reinstallation of set screws.
| Lift Off Speed FRXF/FRXG 550 | 700 rpm |
|---|---|
| Lift Off Speed FRXF/FRXG 700 | 350 rpm |
| Shaft Finish Requirement | 125 micro inch or finer |
Yes, the backstop rotational axis can be from horizontal to vertical, and the torque arm can be mounted at any desired angle.
Maximum operational speed is 2100 rpm.
Mobilgrease XHP 221 or equivalent.
The backstop may have been damaged and should be returned to RINGSPANN CORPORATION for inspection.