Radio Frequency Systems RADIAFLEX® Coaxial Cable Connectors P02 Series Installation Instruction

Installation instructions for Radio Frequency Systems RADIAFLEX 7/8 inch Premium Connectors, P02 series, for qualified personnel.


Radio Frequency Systems RADIAFLEX® Coaxial Cable Connectors P02 Series Installation Instruction - cover page
Brand
Radio Frequency Systems
Category
Other Electronics
Document type
Installation Guide
Language
English
Pages
4
File format
PDF
File size
6.5 MB
Published
19 November, 2026
Updated
19 November, 2026
MD5 checksum
5DDA085B5154D5B4B2D37E2FFE1949A7

About this manual

This document provides installation instructions for Radio Frequency Systems RADIAFLEX 7/8 inch Premium Connectors in the P02 series. It is written for qualified and experienced personnel and covers required tools, safety precautions, cable preparation, connector assembly, and heat shrink sleeve installation.

The procedure includes trimming and flaring the cable, assembling the connector without turning the front part, tightening the back-nut to the recommended torque, and shrinking the sleeve while observing the stated temperature limits.

What's inside

  • Required tools and materials
  • Safety precautions
  • Cable preparation and trimming
  • Universal Trimming Tool procedure
  • Connector assembly
  • Heat shrink sleeve installation
  • Torque and temperature limits
  • PIM performance notes

Specifications

Recommended tightening torque30 – 35 Nm (22.2 – 25.8 ft.-lb.)
Cable straightening lengthmin. 500 mm (20 in)
Cable insertion before main bladeat least 40 mm (1.6 in)
Connector pre-heat temperatureapprox. 60°C (140°F)
Maximum cable jacket temperature70°C (158°F)
Heat shrink sleeve shrinking temperature~130°C (266°F)
Sandpaper grit~280 grain
Wrench size32 mm (1 1/4 in)

Frequently asked questions

What torque should be used to tighten the connector?

Tighten the back-nut only to 30 – 35 Nm (22.2 – 25.8 ft.-lb.), keeping the connector body steady and never turning the front part.

What safety precautions are required?

Protective gloves are required for sharp blades, and heat-resistant gloves are required for hot conditions.

What tools are needed for installation?

The installation uses the Universal Trimming Tool TRIM-SET-R78-P02, a heat shrink sleeve, knife, brush, hot-air gun or gas blow torch, solvent cleanser, sandpaper, cleaning cloth, and 32 mm wrenches.

What temperature limits apply during heat shrinking?

Pre-heat the connector to about 60°C (140°F), keep the cable jacket at or below 70°C (158°F), and shrink the sleeve at about 130°C (266°F).