Installation instructions for Radio Frequency Systems RADIAFLEX 7/8 inch Premium Connectors, P02 series, for qualified personnel.
This document provides installation instructions for Radio Frequency Systems RADIAFLEX 7/8 inch Premium Connectors in the P02 series. It is written for qualified and experienced personnel and covers required tools, safety precautions, cable preparation, connector assembly, and heat shrink sleeve installation.
The procedure includes trimming and flaring the cable, assembling the connector without turning the front part, tightening the back-nut to the recommended torque, and shrinking the sleeve while observing the stated temperature limits.
| Recommended tightening torque | 30 – 35 Nm (22.2 – 25.8 ft.-lb.) |
|---|---|
| Cable straightening length | min. 500 mm (20 in) |
| Cable insertion before main blade | at least 40 mm (1.6 in) |
| Connector pre-heat temperature | approx. 60°C (140°F) |
| Maximum cable jacket temperature | 70°C (158°F) |
| Heat shrink sleeve shrinking temperature | ~130°C (266°F) |
| Sandpaper grit | ~280 grain |
| Wrench size | 32 mm (1 1/4 in) |
Tighten the back-nut only to 30 – 35 Nm (22.2 – 25.8 ft.-lb.), keeping the connector body steady and never turning the front part.
Protective gloves are required for sharp blades, and heat-resistant gloves are required for hot conditions.
The installation uses the Universal Trimming Tool TRIM-SET-R78-P02, a heat shrink sleeve, knife, brush, hot-air gun or gas blow torch, solvent cleanser, sandpaper, cleaning cloth, and 32 mm wrenches.
Pre-heat the connector to about 60°C (140°F), keep the cable jacket at or below 70°C (158°F), and shrink the sleeve at about 130°C (266°F).