About this manual

The Pietro Fiorentini HBC 975 is a safety device designed to quickly interrupt gas flow when pressure reaches a set value. It is primarily used in high-pressure transmission systems and medium-pressure gas distribution networks, suitable for natural gas, oil, hydrogen, and biomethane applications.

Key features include a response time within 1 second, a top-entry design for easy maintenance without removing the valve body from the pipework, and the ability to retrofit existing pressure regulators. The valve can be tripped automatically, locally via a button, or remotely via system monitoring.

What's inside

  • Area of Application
  • Features and Calibration ranges
  • Competitive advantages
  • Materials and Approvals
  • Settings table
  • Sizing

Specifications

Design pressureup to 10.2 MPa
Ambient temperature rangefrom -20 °C to +60 °C
Inlet gas temperature rangefrom -20 °C to +60 °C
Maximum inlet pressure10 MPa
Accuracy classup to 2.5
Over pressure setting rangefrom 0.02 MPa to 9 MPa
Under pressure setting rangefrom 0.02 MPa to 9 MPa
Nominal dimensionsDN 100 / 4” to DN 300 / 12”
Body material (ANSI 300/600)Cast steel ASTM A 352 LCC
Body material (ANSI 150/PN 16)Cast steel ASTM A 216 WCB
Stem materialAISI 416 stainless steel
Construction standardEN 14382

Frequently asked questions

What is the response time of the HBC 975 valve?

The valve ensures tripping within 1 second.

How can the HBC 975 valve be tripped?

It can be tripped automatically when the set-point is exceeded, locally by pressing a button, or remotely via system monitoring.

How is the HBC 975 valve reset?

The restoration of normal operating conditions is carried out in a purely manual manner after verifying and solving the causes of tripping.

Is the HBC 975 suitable for retrofitting?

Yes, its modular design allows retrofitting on existing pressure regulators in the field without piping modifications.