Philips WL345W UV-C luminaire user manual covering electrical characteristics, installation requirements, safety warnings, and maintenance instructions.
This user manual covers the Philips WL345W UV-C luminaire, an indoor wall-mount device for germicidal disinfection using a 25 W TUV T5 lamp.
It provides electrical characteristics, installation and commissioning requirements, UV-C safety markings, maintenance procedures, and warnings about improper use and hazardous failure modes. This manual is written in Chinese.
| Lamp type | 1x TUV T5 25W |
|---|---|
| Supply voltage | 220-240V 50/60Hz |
| Max ambient temperature | 40°C |
| Useful lamp lifetime | 9000 hrs |
| UV-C risk group | 3 (IEC 62471) |
UV-C runs from 200 to 280 nm and is used for disinfection and germicidal applications.
The ceiling height must be at least 2.6 m.
They should be cleaned at least every 6 months.
It must be replaced by the manufacturer, his service agent, or a similar qualified person.