The Philips UVCC200 UV‑C Disinfection Chamber is a countertop appliance designed to disinfect hard‑surface items such as phones, utensils and other non‑medical objects using 80 W of 253.7 nm UV‑C light. The manual provides technical parameters, a structural diagram, and step‑by‑step installation guidance.
Operational instructions cover proper object placement, recommended disinfection times, safety precautions, routine cleaning, and troubleshooting. Maintenance advice includes lamp‑tube replacement, handling of broken tubes, and environmental disposal requirements.
| Dimensions | 560 × 560 × 660 mm |
|---|---|
| Volume | 110 L |
| Weight | 22 kg |
| Power | 80 W |
| Input Voltage | 220‑240 V~ |
| Frequency | 50‑60 Hz |
| Fuse Protection | 5 A, 250 V~ |
| Disinfection Method | 253.7 nm UV‑C |
| Operating Temperature Range | 10‑30 °C |
| Storage Temperature Range | -20‑60 °C |
| Ambient Humidity Range | 10‑90 % |
No, the product is not intended or approved for disinfecting medical devices or for medical purposes.
Use a socket rated above 5 A with a reliable grounding wire.