People Electric RDC8Z Series High Voltage DC Contactor User Manual

User manual for the People Electric RDC8Z series high voltage DC contactor, covering installation, wiring, specifications, and precautions.


People Electric RDC8Z Series High Voltage DC Contactor User Manual - cover page
Brand
People Electric
Category
switch
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
4.5 MB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
19030D4E26941C90A66DC966E3B27D4D

About this manual

The manual covers the People Electric RDC8Z series high voltage DC contactor for applications such as new energy vehicles, engineering machinery, charging piles and stations, power supply equipment, energy storage systems, photovoltaic systems, and uninterruptible power supplies. It describes the operating environment, contact and performance parameters, wiring, dimensions, installation torque, warranty, control power requirements, and precautions.

Key parameters include a main contact rating of 1000 V/300 A DC, auxiliary contact rating of 5 A, pull-in voltage of 9-36 V, release voltage of 5-7 V, dielectric strength of 10 kV DC for 1 minute between main contacts, insulation resistance of 50 MΩ, electrical life up to 8000 cycles at 500 VDC/300 A, and mechanical life of 300000 cycles. This manual is written in Chinese.

What's inside

  • Product application
  • Operating environment
  • Contact parameters
  • Performance parameters
  • Product wiring diagram
  • Product warranty
  • Control power supply
  • Installation
  • Product outline dimensions
  • Precautions

Specifications

Operating temperature-40 to 85 °C
Humidity5% to 85% RH
Pollution degreeII
AltitudeBelow 2000 m
Main contact form1NO
Main contact maximum load1000 V / 300 A DC
Auxiliary contact rated current5 A
Main contact maximum breaking voltage120 VDC
Pull-in voltage9-36 V
Pull-in time≤30 ms
Release voltage5-7 V
Release time10 ms
Dielectric strength (main contact)10 kV DC for 1 min
Dielectric strength (main contact to coil)3500 V DC for 1 min
Insulation resistance50 MΩ
Electrical life at 1000 VDC/300 A1000 cycles
Electrical life at 750 VDC/300 A3000 cycles
Electrical life at 500 VDC/300 A8000 cycles
Mechanical life300000 cycles
Main contact connection torque8-10 Nm
Base installation torque2-3 Nm
Whole-machine warranty1 year

Frequently asked questions

What is the operating temperature range?

The operating temperature range is -40 °C to 85 °C.

What is the main contact rating?

The main contact maximum load is 1000 V/300 A DC.

What is the mechanical life?

The mechanical life is 300000 operations.

What torque is specified for main contact connections?

The main contact connection torque is 8-10 Nm.